All terms
Notified Body
EU-designated organization that assesses conformity of medical devices under MDR and IVDR.
Reviewed by Christian Espinosa, Founder, Blue Goat CyberLast reviewed May 5, 2026
Definition
A Notified Body is an organization designated by an EU Member State competent authority (and listed in NANDO) to carry out conformity assessment tasks under Regulation (EU) 2017/745 (MDR) or 2017/746 (IVDR) before a device is placed on the EU market. Designation itself is governed by Implementing Regulation (EU) 2017/2185 and the joint assessment process. What the regulation says
Under the EU Medical Device Regulation (MDR 2017/745) and In Vitro Diagnostic Regulation (IVDR 2017/746), Notified Bodies are conformity assessment bodies designated and monitored by national authorities to ensure that MedTech products meet the necessary safety and performance requirements before market placement. Their responsibilities include auditing manufacturers' quality management systems, assessing technical documentation, and issuing CE certificates, as detailed in MDR Annex VII and IVDR Annex VII.What this means in practice
Under MDR/IVDR, Notified Body involvement is required for all devices above Class I (non-sterile, non-measuring, non-reusable surgical) and above IVD Class A non-sterile. As of 2026 there are approximately 50 MDR-designated and 15 IVDR-designated Notified Bodies, versus 80+ under the prior directives, which has driven multi-year queue times. The Commission and MDCG have issued repeated guidance (MDCG 2022-4, MDCG 2022-14, MDCG 2023-3) to increase capacity. Notified Bodies audit the quality management system, review technical documentation, issue CE certificates (valid up to 5 years), and conduct annual surveillance audits including unannounced audits per Implementing Regulation (EU) 2013/920.Examples
- BSI (UK/NL), TUV SUD (DE), TUV Rheinland (DE), DEKRA (DE), DNV (NO), IMQ (IT) are among the most active MDR Notified Bodies.
- A Class IIb implantable receives Annex IX Chapter II technical documentation assessment on a representative device from each generic device group.
- Class III and implantables trigger scrutiny procedure (Article 54) and expert panel consultation for certain novel devices.
Common pitfalls
- •Submitting incomplete technical documentation. Notified Bodies charge for each round of review and clock the review time against contractual SLAs.
- •Assuming a legacy MDD/IVDD Notified Body will automatically be designated for MDR/IVDR. Designation is per-code and per-regulation.
- •Not planning for unannounced audits at critical suppliers. Article 44 of MDR requires the manufacturer to ensure the Notified Body has access.
- •Confusing Notified Body with Competent Authority. Notified Bodies do conformity assessment; Competent Authorities do market surveillance and vigilance oversight.
Frequently asked questions
Match your device MDA/MDN/MDS or IVR/IVS/IVT codes to the Notified Body's scope in NANDO. Factor in queue length, language, cost, and prior sector experience (active implantables, IVDs, software) - these vary widely.
Cross-references
Related terms
Shared paths + categoryRegulatory
CE Mark
Mandatory European conformity mark for medical devices placed on the EU market.
EU MDR Essentials · adjacentIVDR Essentials · adjacent
Regulatory
EUDAMED
European Database on Medical Devices.
EU MDR Essentials · adjacentIVDR Essentials · adjacent
Regulatory
EU In Vitro Diagnostic Regulation(IVDR)
Regulation (EU) 2017/746 governing in vitro diagnostic medical devices in the EU.
EU MDR EssentialsIVDR Essentials
Regulatory
EU Medical Device Regulation(MDR)
Regulation (EU) 2017/745 governing medical devices in the European Union.
EU MDR Essentials
Post-Market
Field Safety Corrective Action(FSCA)
Action taken to reduce a risk of serious deterioration in health associated with a device.
EU MDR EssentialsIVDR Essentials
Regulatory
General Safety and Performance Requirements(GSPRs)
Annex I requirements under EU MDR/IVDR that every device must demonstrate it meets.
IVDR Essentials · adjacent
Latest in MedTech
Primary references
3 sourcesLink health: 1 verified 2 unchecked· last checked 2026-06-20
European Commission·1MDCG·1EUR-Lex·1
- 1NANDO Notified Body databaseUncheckedEuropean Commissionec.europa.eu
- 2MDCG 2022-11 Notified Body transferUncheckedMDCGhealth.ec.europa.eu
- 3Regulation (EU) 2017/745 Chapter IVVerifiedEUR-Lexeur-lex.europa.eu
Inline markers like [1] jump to the matching reference above.