IEC 82304-1
Standard for health software products - covering general requirements for product safety.
Definition
IEC 82304-1 complements IEC 62304 by addressing health software products as standalone products, with requirements covering identification, requirements, validation, accompanying information, and post-market activities. IEC 82304-1:2016 applies to health software products intended to run on general computing platforms without dedicated hardware, including both medical device software and wellness software. It relies on IEC 62304 for the software lifecycle but adds requirements for the whole product, such as product requirements, product validation and accompanying documents. It is commonly used for health apps and is related to the ISO/TS 82304-2 health app quality label.What this means in practice
Particularly relevant for SaMD distributed independently of any specific hardware (mobile apps, web platforms, cloud services).Examples
- A mobile application intended for diagnosing skin conditions using image analysis would fall under IEC 82304-1 as standalone health software.
- A web-based platform providing dosage calculations for medication, used independently by healthcare professionals, is an example of health software addressed by this standard.
- Cloud-based software for managing patient records and providing clinical decision support, not tied to a specific hardware device, exemplifies the application of IEC 82304-1.
- •A common pitfall is assuming compliance with IEC 62304 alone is sufficient for standalone health software, neglecting the broader lifecycle requirements introduced by IEC 82304-1.
- •Manufacturers often err by not adequately defining the intended use and user profiles for their health software, leading to validation shortcomings.
- •Another mistake is overlooking the critical post-market surveillance activities specifically for standalone software, which differ from hardware-integrated software.
- •Underestimating the cybersecurity risks inherent in standalone health software, especially for products connected to networks or cloud services, is a significant pitfall.
Frequently asked questions
Related terms
Grouped by themeEditor's picks
· Hand-selected related conceptsMore in Standards
· Same categoryStandard practice for marking medical devices and other items for safety in the magnetic resonance environment.
Performance of a clinical function whose loss or degradation would result in unacceptable risk.
European standards cited by reference in the Official Journal of the EU that give manufacturers a presumption of conformity with corresponding legal requirements.
ICH Good Clinical Practice revision with Principles and Annex 1 adopted in January 2025 and Annex 2 in June 2026.
Where this term appears across MedTech Terms.
Latest in MedTech
Sources
3 sourcesSources support the definition or relevant regulatory context, not necessarily every claim on this page. Each is graded against our source-tier hierarchy so you can see what rests on binding law versus commentary.
- 1IEC 82304-1Tier 1 VerifiedIECwebstore.iec.ch
- 2FDA Recognized Consensus StandardsTier 2 VerifiedFDAaccessdata.fda.gov
- 3ISO Standards Catalogue - HealthTier 1 VerifiedISOiso.org
Inline markers like [1] jump to the matching reference above.