    Post-Market

    Medical Device Vigilance

    In one line
    Reporting and management of serious incidents and field safety corrective actions.
    Definition
    Vigilance is the regulatory process by which manufacturers report serious incidents and field safety corrective actions involving CE-marked devices to the relevant Competent Authorities. Equivalent obligations apply under FDA's Medical Device Reporting (MDR) regulation in 21 CFR Part 803. Under EU MDR Article 87, serious incidents must be reported no later than 15 days after awareness, within 2 days for a serious public health threat, and within 10 days for death or unanticipated serious deterioration in health. Manufacturers must investigate each incident, cooperate with authorities and report field safety corrective actions before taking them, except in urgent cases. MDCG 2023-3 provides vigilance guidance.
    Why it matters
    Vigilance feeds back into PMS, risk management, and CAPA. Timeliness of reporting is closely scrutinized by regulators.
    Common pitfalls
    • •Failing to report serious incidents within the stipulated regulatory timelines can lead to significant non-compliance issues, including fines and market access restrictions.
    • •Incomplete or insufficient investigation of reported incidents can hinder effective root cause analysis and delay the implementation of necessary corrective and preventive actions.
    • •Not adequately documenting the decision-making process for incident reporting and Field Safety Corrective Actions can create challenges during regulatory audits and inspections.
    • •Assuming that 'no incidents' means 'no problems' and neglecting proactive post-market surveillance activities, which might uncover potential issues before they escalate to serious incidents.
    • •Misinterpreting the definitions of 'serious incident' or 'serious public health threat,' leading to underreporting or incorrect classification of events.
    Sources
    Open full page
    Select term B to compare.

    Why compare MedTech terms side by side?

    MedTech terminology is full of pairs that look interchangeable but carry very different regulatory, clinical, and commercial consequences. Picking the wrong framework, pathway, or standard early in a project can add months to a submission, invalidate clinical evidence, or trigger an audit finding. Side-by-side comparison is the fastest way to surface those differences before they become costly mistakes.

    Each comparison on this page pulls from the same vendor-neutral, sourced definitions used throughout the MedTech Terms glossary. You see the one-line summary, the formal definition, why it matters in practice, common pitfalls, and the primary sources (FDA guidance, EU MDR/IVDR articles, ISO/IEC standards, MDCG documents, IMDRF principles) that back each entry. That makes the comparison defensible in regulatory strategy memos, design reviews, and submission narratives.

    Common comparison patterns

    How to use this tool

    Pick term A and term B from the dropdowns, or click a preset above. The URL updates with both slugs so you can bookmark or share the exact comparison with a colleague, a notified body reviewer, or your regulatory consultant. Click Open full page on either side for the complete entry, including FAQs, related terms, and the full citation list. If you are not sure which term to start with, browse the Categories view or the A-Z index.

    MedTech Terms is a vendor-neutral community resource sponsored by Blue Goat Cyber. Definitions are written for educational use and are not legal or regulatory advice.