    Post-Market

    Trend Reporting (MDR/MIR)

    In one line
    Obligation to report statistically significant increases in expected non-serious incidents.
    Definition
    EU MDR Article 88 requires trend reporting when expected adverse events show a clinically significant increase. Sponsors define the trend signals, thresholds, and analysis frequency in the PMS plan. Trend reports cover incidents that are not serious incidents and expected undesirable side effects that could significantly affect the benefit-risk analysis, when their frequency or severity increases significantly. Manufacturers must define how they detect a statistically significant increase, the observation period and thresholds, in the PMS plan. Reports are submitted through EUDAMED using the manufacturer trend report form.
    Why it matters
    Trend reporting closes the gap between routine vigilance (per-event) and PMS evaluation (periodic) - and is one of the more difficult areas for PRRCs to operationalize.
    Common pitfalls
    • •A common pitfall is failing to establish clear, objective trend signals and thresholds in the PMS plan, leading to subjective interpretations and inconsistent reporting.
    • •Manufacturers often struggle with integrating trend reporting data effectively from various sources, such as complaint handling, vigilance, and clinical follow-up activities.
    • •One mistake is not adequately documenting the rationale for chosen trend thresholds, which can lead to difficulties during regulatory audits.
    • •Another pitfall is delaying the aggregation and analysis of post-market data, which can result in missing critical trends until it is too late to act proactively.
    • •Failing to allocate sufficient resources, including personnel and appropriate software tools, for continuous trend analysis is a frequent oversight.
    Sources
    Open full page
    Select term B to compare.

    Why compare MedTech terms side by side?

    MedTech terminology is full of pairs that look interchangeable but carry very different regulatory, clinical, and commercial consequences. Picking the wrong framework, pathway, or standard early in a project can add months to a submission, invalidate clinical evidence, or trigger an audit finding. Side-by-side comparison is the fastest way to surface those differences before they become costly mistakes.

    Each comparison on this page pulls from the same vendor-neutral, sourced definitions used throughout the MedTech Terms glossary. You see the one-line summary, the formal definition, why it matters in practice, common pitfalls, and the primary sources (FDA guidance, EU MDR/IVDR articles, ISO/IEC standards, MDCG documents, IMDRF principles) that back each entry. That makes the comparison defensible in regulatory strategy memos, design reviews, and submission narratives.

    Common comparison patterns

    How to use this tool

    Pick term A and term B from the dropdowns, or click a preset above. The URL updates with both slugs so you can bookmark or share the exact comparison with a colleague, a notified body reviewer, or your regulatory consultant. Click Open full page on either side for the complete entry, including FAQs, related terms, and the full citation list. If you are not sure which term to start with, browse the Categories view or the A-Z index.

    MedTech Terms is a vendor-neutral community resource sponsored by Blue Goat Cyber. Definitions are written for educational use and are not legal or regulatory advice.