    Process Capability (Cp/Cpk) and SPC

    In one line
    Statistical metrics and methods for monitoring whether a process meets its specifications.
    Definition
    Statistical Process Control (SPC) uses control charts to monitor process stability. Process capability indices Cp and Cpk quantify how well a stable process fits within specification limits, with Cpk accounting for centering. SPC uses charts such as X-bar and R, individuals and p-charts, with rules that flag shifts and trends before parts go out of specification. Capability should only be calculated once a process is shown to be stable. In medical device manufacturing, SPC data supports process validation, ongoing monitoring under ISO 13485 clause 8.2.5 and CAPA trend analysis.
    Why it matters
    Process validation per the FDA/GHTF guidance expects capable and stable processes. Common medical-device targets are Cpk ≥ 1.33 for routine attributes and ≥ 1.67 for safety-critical ones.
    Common pitfalls
    • •A common pitfall is calculating Cpk on unstable processes, leading to misleading capability assessments.
    • •Misinterpreting a high Cpk value as a guarantee of product quality without considering other factors like measurement system variability is a mistake.
    • •Failing to regularly monitor and react to SPC control chart signals can lead to process drift and non-conforming products.
    • •Only focusing on Cpk without attention to critical process parameters and their clinical impact is a pitfall.
    • •Setting arbitrary Cpk targets without a rational basis tied to risk assessment and product requirements can lead to inefficient resource allocation or inadequate quality control.
    Open full page
    Select term B to compare.

    Why compare MedTech terms side by side?

    MedTech terminology is full of pairs that look interchangeable but carry very different regulatory, clinical, and commercial consequences. Picking the wrong framework, pathway, or standard early in a project can add months to a submission, invalidate clinical evidence, or trigger an audit finding. Side-by-side comparison is the fastest way to surface those differences before they become costly mistakes.

    Each comparison on this page pulls from the same vendor-neutral, sourced definitions used throughout the MedTech Terms glossary. You see the one-line summary, the formal definition, why it matters in practice, common pitfalls, and the primary sources (FDA guidance, EU MDR/IVDR articles, ISO/IEC standards, MDCG documents, IMDRF principles) that back each entry. That makes the comparison defensible in regulatory strategy memos, design reviews, and submission narratives.

    Common comparison patterns

    How to use this tool

    Pick term A and term B from the dropdowns, or click a preset above. The URL updates with both slugs so you can bookmark or share the exact comparison with a colleague, a notified body reviewer, or your regulatory consultant. Click Open full page on either side for the complete entry, including FAQs, related terms, and the full citation list. If you are not sure which term to start with, browse the Categories view or the A-Z index.

    MedTech Terms is a vendor-neutral community resource sponsored by Blue Goat Cyber. Definitions are written for educational use and are not legal or regulatory advice.