    Regulatory

    Refuse to Accept(RTA)

    In one line
    FDA administrative decision that a submission is incomplete and won't be substantively reviewed.
    Definition
    Refuse to Accept (RTA) is FDA's administrative review of 510(k) submissions to determine whether they meet a minimum threshold of acceptability for substantive review based on a checklist. FDA applies its Refuse to Accept checklist within the first 15 calendar days of receiving a 510(k), checking that required elements such as device description, comparison to the predicate, labeling and performance data are present. It is an administrative completeness check, not a scientific review. The eSTAR template, mandatory for most 510(k)s since October 2023, builds many of these checks into the form and largely replaces the separate RTA screen for those submissions.
    Why it matters
    RTA decisions occur in the first 15 calendar days of the review clock. If FDA finds missing checklist items, the submission is held (RTA hold) and the 90-day review clock stops until the sponsor submits the missing content. Two consecutive RTA holds can effectively add 60 to 120 days to the timeline. Similar acceptance reviews exist for De Novo (Acceptance Review) and PMA (Filing Review). The most common RTA triggers in 2024-2025 have shifted from labeling and administrative gaps to cybersecurity content: missing SBOM, no threat model, no vulnerability management plan, no coordinated disclosure policy under Section 524B.
    Common pitfalls
    • •Ignoring the eCopy or eSTAR technical validation errors before submission. Technical failures cause immediate RTA.
    • •Treating cybersecurity content as optional for 510(k). Under 524B, any cyber device submission without SBOM, CVD policy, and vulnerability management triggers RTA.
    • •Inconsistent indications-for-use wording across the cover letter, Section 4, and labeling. This is the single most common non-cyber RTA reason.
    • •Submitting near a quarter-end deadline without a full internal RTA checklist review. FDA follows the checklist strictly; sponsors should too.
    Open full page
    Select term B to compare.

    Why compare MedTech terms side by side?

    MedTech terminology is full of pairs that look interchangeable but carry very different regulatory, clinical, and commercial consequences. Picking the wrong framework, pathway, or standard early in a project can add months to a submission, invalidate clinical evidence, or trigger an audit finding. Side-by-side comparison is the fastest way to surface those differences before they become costly mistakes.

    Each comparison on this page pulls from the same vendor-neutral, sourced definitions used throughout the MedTech Terms glossary. You see the one-line summary, the formal definition, why it matters in practice, common pitfalls, and the primary sources (FDA guidance, EU MDR/IVDR articles, ISO/IEC standards, MDCG documents, IMDRF principles) that back each entry. That makes the comparison defensible in regulatory strategy memos, design reviews, and submission narratives.

    Common comparison patterns

    How to use this tool

    Pick term A and term B from the dropdowns, or click a preset above. The URL updates with both slugs so you can bookmark or share the exact comparison with a colleague, a notified body reviewer, or your regulatory consultant. Click Open full page on either side for the complete entry, including FAQs, related terms, and the full citation list. If you are not sure which term to start with, browse the Categories view or the A-Z index.

    MedTech Terms is a vendor-neutral community resource sponsored by Blue Goat Cyber. Definitions are written for educational use and are not legal or regulatory advice.