    Quality & Risk

    Production and Process Controls

    In one line
    21 CFR 820.70 / ISO 13485 §7.5 requirements that production processes be planned, controlled, monitored, and validated where needed.
    Definition
    Covers documented procedures, environmental control, contamination control, equipment maintenance, personnel hygiene, and process changes. The clauses where 'process validation', 'in-process controls', and 'work instructions' all live. Under the QMSR, these requirements sit in ISO 13485 clauses 7.5 and 6.4, covering control of production, cleanliness, installation, servicing, process validation, identification, traceability and preservation of product. Processes whose output cannot be fully verified by later inspection, such as sterilization, sealing or molding, must be validated. Monitoring data such as statistical process control is often reviewed during inspections.
    Why it matters
    Among the most frequently cited subparts in FDA Form 483 observations.
    Common pitfalls
    • •Failing to validate all processes, even those not considered "special processes," can lead to non-conformities.
    • •Inadequate documentation of process changes, including justifications and verification activities, is a common deficiency.
    • •Not consistently monitoring and controlling environmental conditions, especially in cleanroom environments, can compromise product quality.
    • •Neglecting routine equipment calibration and maintenance can directly impact process stability and product conformity.
    • •Assuming personnel are adequately trained without documented evidence of their competency in specific production tasks is a critical oversight.
    Open full page
    Select term B to compare.

    Why compare MedTech terms side by side?

    MedTech terminology is full of pairs that look interchangeable but carry very different regulatory, clinical, and commercial consequences. Picking the wrong framework, pathway, or standard early in a project can add months to a submission, invalidate clinical evidence, or trigger an audit finding. Side-by-side comparison is the fastest way to surface those differences before they become costly mistakes.

    Each comparison on this page pulls from the same vendor-neutral, sourced definitions used throughout the MedTech Terms glossary. You see the one-line summary, the formal definition, why it matters in practice, common pitfalls, and the primary sources (FDA guidance, EU MDR/IVDR articles, ISO/IEC standards, MDCG documents, IMDRF principles) that back each entry. That makes the comparison defensible in regulatory strategy memos, design reviews, and submission narratives.

    Common comparison patterns

    How to use this tool

    Pick term A and term B from the dropdowns, or click a preset above. The URL updates with both slugs so you can bookmark or share the exact comparison with a colleague, a notified body reviewer, or your regulatory consultant. Click Open full page on either side for the complete entry, including FAQs, related terms, and the full citation list. If you are not sure which term to start with, browse the Categories view or the A-Z index.

    MedTech Terms is a vendor-neutral community resource sponsored by Blue Goat Cyber. Definitions are written for educational use and are not legal or regulatory advice.