    Regulatory

    IVDR Transitional Provisions

    In one line
    Extended deadlines under Regulation (EU) 2024/1860 allowing legacy IVDs to remain on the market until 2027 to 2029 based on class.
    Definition
    Article 110 of the IVDR, as amended by Regulation (EU) 2022/112 and Regulation (EU) 2024/1860, extends transitional deadlines for devices lawfully placed on the market under the IVDD. Class D legacy devices may remain on the market until 31 December 2027, Class C until 31 December 2028, and Class B and Class A sterile until 31 December 2029, provided conditions in Article 110(3) are met (no significant changes, IVDR-compliant PMS/vigilance/registration, written agreement with a notified body by set milestones).
    Why it matters
    The 2024 amendment also introduced a mandatory manufacturer notification via EUDAMED when discontinuing supply of a device that might cause a serious shortage (Article 110a), and made the transitional relief conditional on active progression toward IVDR certification, not passive coasting.
    Common pitfalls
    • •Treating the extended deadlines as automatic. Manufacturers must have a signed notified-body agreement by 26 September 2025 for Class D, 26 May 2026 for Class C, and 26 May 2027 for Class B/A sterile.
    • •Missing the Article 110a supply-disruption notice, which is mandatory 6 months in advance.
    Open full page
    Select term B to compare.

    Why compare MedTech terms side by side?

    MedTech terminology is full of pairs that look interchangeable but carry very different regulatory, clinical, and commercial consequences. Picking the wrong framework, pathway, or standard early in a project can add months to a submission, invalidate clinical evidence, or trigger an audit finding. Side-by-side comparison is the fastest way to surface those differences before they become costly mistakes.

    Each comparison on this page pulls from the same vendor-neutral, sourced definitions used throughout the MedTech Terms glossary. You see the one-line summary, the formal definition, why it matters in practice, common pitfalls, and the primary sources (FDA guidance, EU MDR/IVDR articles, ISO/IEC standards, MDCG documents, IMDRF principles) that back each entry. That makes the comparison defensible in regulatory strategy memos, design reviews, and submission narratives.

    Common comparison patterns

    How to use this tool

    Pick term A and term B from the dropdowns, or click a preset above. The URL updates with both slugs so you can bookmark or share the exact comparison with a colleague, a notified body reviewer, or your regulatory consultant. Click Open full page on either side for the complete entry, including FAQs, related terms, and the full citation list. If you are not sure which term to start with, browse the Categories view or the A-Z index.

    MedTech Terms is a vendor-neutral community resource sponsored by Blue Goat Cyber. Definitions are written for educational use and are not legal or regulatory advice.