    Regulatory

    Summary of Safety and Performance (IVDR)(SSP)

    In one line
    Publicly accessible summary that manufacturers of Class C and D IVDs must prepare and upload to EUDAMED.
    Definition
    Article 29 of the IVDR requires manufacturers of Class C and D devices (except performance studies) to draw up a Summary of Safety and Performance. The SSP is written in a way clearly understood by the intended user and, where relevant, the patient, is validated by the notified body, and is made available to the public through EUDAMED. It covers the intended purpose, a summary of scientific validity and analytical and clinical performance, metrological traceability, residual risks, and the suggested profile and training of users.
    Why it matters
    The SSP is the IVDR counterpart of the MDR SSCP. It plays an important transparency role: hospitals, laboratories, and patients can review claimed performance and post-market findings for high-risk IVDs without accessing the technical file.
    Common pitfalls
    • •Manufacturers often underestimate the effort required to make the SSP accessible to a lay audience, leading to documents that are too technical or use excessive jargon.
    • •Failing to adequately update the SSP throughout the device's lifecycle can lead to inconsistencies between the public document and the most current safety and performance data.
    • •Not obtaining proper notified body validation for the SSP before its publication can result in non-compliance and delays in market access or continued availability.
    Open full page
    Select term B to compare.

    Why compare MedTech terms side by side?

    MedTech terminology is full of pairs that look interchangeable but carry very different regulatory, clinical, and commercial consequences. Picking the wrong framework, pathway, or standard early in a project can add months to a submission, invalidate clinical evidence, or trigger an audit finding. Side-by-side comparison is the fastest way to surface those differences before they become costly mistakes.

    Each comparison on this page pulls from the same vendor-neutral, sourced definitions used throughout the MedTech Terms glossary. You see the one-line summary, the formal definition, why it matters in practice, common pitfalls, and the primary sources (FDA guidance, EU MDR/IVDR articles, ISO/IEC standards, MDCG documents, IMDRF principles) that back each entry. That makes the comparison defensible in regulatory strategy memos, design reviews, and submission narratives.

    Common comparison patterns

    How to use this tool

    Pick term A and term B from the dropdowns, or click a preset above. The URL updates with both slugs so you can bookmark or share the exact comparison with a colleague, a notified body reviewer, or your regulatory consultant. Click Open full page on either side for the complete entry, including FAQs, related terms, and the full citation list. If you are not sure which term to start with, browse the Categories view or the A-Z index.

    MedTech Terms is a vendor-neutral community resource sponsored by Blue Goat Cyber. Definitions are written for educational use and are not legal or regulatory advice.