    Post-Market Surveillance Plan (IVDR)

    In one line
    Manufacturer-maintained plan under Article 79 describing how safety and performance data are systematically collected once an IVD is on the market.
    Definition
    Article 79 and Annex III of the IVDR require every manufacturer to plan, establish, document, implement, maintain, and update a post-market surveillance system proportionate to the risk class and appropriate for the type of device. The PMS Plan defines the data sources (complaints, PMPF, literature, registries), the indicators and thresholds, and the linkage back into risk management and the performance evaluation.
    Why it matters
    For Class A and B devices the outputs feed a PMS Report (Article 80); for Class C and D they feed a Periodic Safety Update Report (PSUR, Article 81) that is reviewed by the notified body for Class C and D and, for Class D, made available through EUDAMED.
    Common pitfalls
    • •A common mistake is creating a generic PMS Plan that does not adequately reflect the specific risks, intended use, or type of a particular IVD, failing to meet the proportionality requirement of Article 79.
    • •Manufacturers often fail to establish clear indicators and thresholds for when a signal constitutes a potential safety concern, leading to reactive rather than proactive post-market surveillance activities.
    • •Another pitfall is not ensuring a robust feedback loop from PMS activities back into the risk management process and performance evaluation, which is critical for ongoing device safety and effectiveness updates.
    Open full page
    Select term B to compare.

    Why compare MedTech terms side by side?

    MedTech terminology is full of pairs that look interchangeable but carry very different regulatory, clinical, and commercial consequences. Picking the wrong framework, pathway, or standard early in a project can add months to a submission, invalidate clinical evidence, or trigger an audit finding. Side-by-side comparison is the fastest way to surface those differences before they become costly mistakes.

    Each comparison on this page pulls from the same vendor-neutral, sourced definitions used throughout the MedTech Terms glossary. You see the one-line summary, the formal definition, why it matters in practice, common pitfalls, and the primary sources (FDA guidance, EU MDR/IVDR articles, ISO/IEC standards, MDCG documents, IMDRF principles) that back each entry. That makes the comparison defensible in regulatory strategy memos, design reviews, and submission narratives.

    Common comparison patterns

    How to use this tool

    Pick term A and term B from the dropdowns, or click a preset above. The URL updates with both slugs so you can bookmark or share the exact comparison with a colleague, a notified body reviewer, or your regulatory consultant. Click Open full page on either side for the complete entry, including FAQs, related terms, and the full citation list. If you are not sure which term to start with, browse the Categories view or the A-Z index.

    MedTech Terms is a vendor-neutral community resource sponsored by Blue Goat Cyber. Definitions are written for educational use and are not legal or regulatory advice.