    Regulatory

    EU In Vitro Diagnostic Regulation(IVDR)

    In one line
    Regulation (EU) 2017/746 governing in vitro diagnostic medical devices in the EU.
    Definition
    Regulation (EU) 2017/746 (IVDR) sets out the regulatory framework for in vitro diagnostic medical devices placed on the EU market, replacing Directive 98/79/EC (IVDD). It introduces a risk-based classification (Class A, B, C, D) aligned with IMDRF principles and dramatically expands the role of Notified Bodies. It applies from May 26, 2022. Under the new rules most IVDs need notified body involvement, compared with roughly a fifth under the old directive. Performance evaluation now covers scientific validity, analytical performance and clinical performance, plus post-market performance follow-up. Transition periods were extended by Regulations (EU) 2022/112 and 2024/1860.
    Why it matters
    Under IVDD, roughly 8% of IVDs required Notified Body review. Under IVDR, that figure rises to roughly 80%. Regulation (EU) 2022/112 and Regulation (EU) 2024/1860 staggered transition deadlines through 2027-2029 to prevent supply shortages. Key new obligations include a Performance Evaluation Report (Annex XIII), Post-Market Performance Follow-up (PMPF), Summary of Safety and Performance (SSP) for Class C/D, EU Reference Laboratories for Class D, EUDAMED registration, and Person Responsible for Regulatory Compliance (PRRC) per Article 15. In-house (LDT) tests are permitted under Article 5(5) only with strict justification.
    Common pitfalls
    • •Assuming legacy IVDD CE certificates transfer automatically. They require a Notified Body application and quality system compliance before the applicable Article 110 deadline.
    • •Under-scoping the Performance Evaluation - IVDR requires scientific validity, analytical performance, and clinical performance as three distinct evidence streams.
    • •Missing the PMPF plan. It is mandatory even for Class B devices and must be reviewed annually (PSUR for C/D).
    • •Treating companion diagnostics as generic IVDs. Article 48 requires consultation with EMA or a national medicines authority.
    Open full page
    Select term B to compare.

    Why compare MedTech terms side by side?

    MedTech terminology is full of pairs that look interchangeable but carry very different regulatory, clinical, and commercial consequences. Picking the wrong framework, pathway, or standard early in a project can add months to a submission, invalidate clinical evidence, or trigger an audit finding. Side-by-side comparison is the fastest way to surface those differences before they become costly mistakes.

    Each comparison on this page pulls from the same vendor-neutral, sourced definitions used throughout the MedTech Terms glossary. You see the one-line summary, the formal definition, why it matters in practice, common pitfalls, and the primary sources (FDA guidance, EU MDR/IVDR articles, ISO/IEC standards, MDCG documents, IMDRF principles) that back each entry. That makes the comparison defensible in regulatory strategy memos, design reviews, and submission narratives.

    Common comparison patterns

    How to use this tool

    Pick term A and term B from the dropdowns, or click a preset above. The URL updates with both slugs so you can bookmark or share the exact comparison with a colleague, a notified body reviewer, or your regulatory consultant. Click Open full page on either side for the complete entry, including FAQs, related terms, and the full citation list. If you are not sure which term to start with, browse the Categories view or the A-Z index.