    Standards

    ISO 10993-1

    In one line
    Biological evaluation of medical devices within a risk management process.
    Definition
    ISO 10993-1:2018 describes the general principles governing the biological evaluation of medical devices within a risk management process, including selection of evaluation tests based on tissue contact and duration. Devices are categorized by nature of contact (surface, externally communicating or implant) and duration (limited up to 24 hours, prolonged up to 30 days, long-term over 30 days), which determines the biological endpoints to address. The standard stresses using existing data, chemical characterization and risk assessment before animal testing. Other parts of the 10993 series describe specific tests. FDA's guidance on ISO 10993-1 adds US-specific expectations.
    Why it matters
    Biocompatibility documentation is a routine requirement for any patient-contacting device. FDA's recognized version aligns with ISO 10993-1:2018 plus FDA-specific guidance.
    Common pitfalls
    • •Failing to integrate biocompatibility evaluation into the overall risk management process can lead to overlooked hazards.
    • •Selecting inappropriate test methods based on incorrect assumptions about device contact or duration can result in inadequate biological evaluation.
    • •Not considering the manufacturing process and its potential impact on the device's biocompatibility can lead to non-conformance.
    • •Ignoring changes in device materials or intended use can invalidate previous biocompatibility assessments.
    • •Solely relying on material certificates without conducting device-specific testing when necessary is a common pitfall.
    Open full page
    Select term B to compare.

    Why compare MedTech terms side by side?

    MedTech terminology is full of pairs that look interchangeable but carry very different regulatory, clinical, and commercial consequences. Picking the wrong framework, pathway, or standard early in a project can add months to a submission, invalidate clinical evidence, or trigger an audit finding. Side-by-side comparison is the fastest way to surface those differences before they become costly mistakes.

    Each comparison on this page pulls from the same vendor-neutral, sourced definitions used throughout the MedTech Terms glossary. You see the one-line summary, the formal definition, why it matters in practice, common pitfalls, and the primary sources (FDA guidance, EU MDR/IVDR articles, ISO/IEC standards, MDCG documents, IMDRF principles) that back each entry. That makes the comparison defensible in regulatory strategy memos, design reviews, and submission narratives.

    Common comparison patterns

    How to use this tool

    Pick term A and term B from the dropdowns, or click a preset above. The URL updates with both slugs so you can bookmark or share the exact comparison with a colleague, a notified body reviewer, or your regulatory consultant. Click Open full page on either side for the complete entry, including FAQs, related terms, and the full citation list. If you are not sure which term to start with, browse the Categories view or the A-Z index.

    MedTech Terms is a vendor-neutral community resource sponsored by Blue Goat Cyber. Definitions are written for educational use and are not legal or regulatory advice.