    Software & AI

    AAMI TIR45(TIR45)

    In one line
    AAMI Technical Information Report providing guidance on applying Agile software development practices within an IEC 62304-compliant medical device software lifecycle.
    Definition
    AAMI TIR45 is a Technical Information Report providing guidance on the use of Agile software development practices (Scrum, Kanban, XP) in the development of medical device software within the framework of IEC 62304. It addresses how Agile incremental and iterative development can be reconciled with the structured documentation, planning, and verification requirements of IEC 62304, ISO 13485, and FDA's software design controls. Topics include backlog management as a planning artifact, definition of done as a verification gate, continuous integration with regulated builds, and how to align sprint cadence with documentation milestones.
    Why it matters
    AAMI TIR45:2023 provides recommendations for using Agile practices in medical device software development alongside applicable standards and FDA guidance. FDA recognizes the complete 2023 report as recognition 13-143, entered May 26, 2025. Declarations to the superseded 2012 edition remain accepted until July 2, 2028. It does not replace IEC 62304 or the manufacturer’s required lifecycle evidence. Do not claim that FDA’s 2002 General Principles of Software Validation guidance references a report first published in 2012.
    Common pitfalls
    • •Adopting Agile without documenting the mapping to IEC 62304 process outputs, the standard requires evidence, not framework choice.
    • •Treating the backlog as the only planning artifact, IEC 62304 still expects a software development plan that backlog items refine.
    • •Skipping the 'definition of done' rigor, without verification evidence per increment, regression and integration testing burdens shift to release time.
    Open full page
    Select term B to compare.

    Why compare MedTech terms side by side?

    MedTech terminology is full of pairs that look interchangeable but carry very different regulatory, clinical, and commercial consequences. Picking the wrong framework, pathway, or standard early in a project can add months to a submission, invalidate clinical evidence, or trigger an audit finding. Side-by-side comparison is the fastest way to surface those differences before they become costly mistakes.

    Each comparison on this page pulls from the same vendor-neutral, sourced definitions used throughout the MedTech Terms glossary. You see the one-line summary, the formal definition, why it matters in practice, common pitfalls, and the primary sources (FDA guidance, EU MDR/IVDR articles, ISO/IEC standards, MDCG documents, IMDRF principles) that back each entry. That makes the comparison defensible in regulatory strategy memos, design reviews, and submission narratives.

    Common comparison patterns

    How to use this tool

    Pick term A and term B from the dropdowns, or click a preset above. The URL updates with both slugs so you can bookmark or share the exact comparison with a colleague, a notified body reviewer, or your regulatory consultant. Click Open full page on either side for the complete entry, including FAQs, related terms, and the full citation list. If you are not sure which term to start with, browse the Categories view or the A-Z index.

    MedTech Terms is a vendor-neutral community resource sponsored by Blue Goat Cyber. Definitions are written for educational use and are not legal or regulatory advice.